Klipper probe as z endstop. com/ztzpidt/waterloo-electrical-engineering-reddit.

3 KB. Then, in the printer. cfg file contains the incorrect settings for using a BLTouch/CRTouch as a virtual z endstop pin. That can't be accurate - you'd be unable to move < 20 if there was an endstop there. Z_offset is the distance between tip of the nozzle and the probe on z axe. # Limits how low of a latency contact is allowed to advance. You may have to do it twice, since the As such, some printers use an endstop for homing the Z axis and a probe for calibrating the mesh. 5mm. See the MANUAL_PROBE command for details on the parameters and the additional commands available while the tool is active. The probe shows triggered as well. You would need to ask the those developers why it’s being shown. Triggering the endstop while it is still some distance from the bed reduces the risk of inadvertent bed This document describes Klipper's automatic calibration system for "delta" style printers. In same cases you will modify your z_offest (ex. In this configuration it is possible offset the mesh so that the (X, Y) reference position applies zero adjustment. After a print job, I drive Z to maximum. . 6 MB) Hi all, trying to setup my CR10S PRO V2 with an EBB36 board Dec 30, 2021 · But shouldn't the probe moved to that position instead? I've tried to find the answer in the code (I have to admit that I'm a Python noob) but it looks like the offset is just used for the bed mesh leveling. Z_OFFSET_APPLY_ENDSTOP¶ Z_OFFSET_APPLY_ENDSTOP: Take the current Z Gcode offset (aka, babystepping), and . cfg change endstop_pin: PA5 to endstop_pin: probe:z_virtual_endstop and comment out or remove position_endstop: 0. KlickyProbe STL's are now located on each probe type directory. cfg file. log (60. cfg file that Klipper reads. endstop_pin: probe:z_virtual_endstop. I use my tmc motors as an endstop to home zmax. Jan 11, 2024 · Also: During homing always only one endstop switch/probe is checked. It' s an "closer" probe, so I invertet the z-min pin in klipper. Upon setting up the config things for the fake BLtouch I get this: I have found like 4 other posts on the internet of people having the same problem and it magically fixing itself or something, so I have no clue what’s wrong. That is the reason you have the (Klicky) probe as virtual endstop on the Z-axes. I don't think you can have two probes and i can't imagine how a probe could probe 2 different points at the same time. So I’ve redone things – as far as I know correctly – but Jan 21, 2018 · Hello! I'm trying to config my delta, but I can't figure out how to get status of Z-min (Z-probe) pin. you need to ether remove the resistor, which is really hard or asign another pin to the Z endstop and put the signal cable of your probe to this pin. Engage this switch by moving the Heater Bed to the rear of the printer until you hear the switch Jan 12, 2024 · Thanks and going to start going through all the steps. phase. Basic Information: Printer Model: -CR10V2 MCU / Printerboard:- BTT SKR v1. May 10, 2017 · The work-probe-20170609 test branch now has code that allows the probe to be used in place of a normal z endstop. Fill out above information and in all cases attach your klippy. 1 (F446) klippy. Example: endstop_pin: probe:z_virtual_endstop. Actual behavior The probe section also creates a virtual "probe:z_virtual_endstop" pin. Contribute to protoloft/klipper_z_calibration development by creating an account on GitHub. If you only want to do homing with the Klicky probe, then set PG15 to the endstop_pin in stepper_z. To enable this feature, one would determine the nozzle coordinates such that the Z probe is above the screws, and then add them to the config file. Fork 1 1. I am having difficulty saving 'Tuned' Z Offset settings. However, there hasn't been any code changes to the endstop checking in years. Oct 4, 2018 · Hi, after updating to the latest version received this error:- Option 'position_endstop' is not valid in section 'stepper_z' This entry in printer. This isn’t new technology, its just new to 3D Sep 23, 2023 · Basic Information: Printer Model: Modified Ender 3v2. If homing is started, the axis moves to the mechanical limit. org/Bed Instead of letting the probe pin touch the print bed, let it touch the nail on your finger. My Marlin config is configured like this: /**. 4r2, I setup my Klipper, test out the motors, fans, thermistors, etc Also I did not install Z endstop so use the Adjusting bed leveling screws using the bed probe¶ This is another way to calibrate the bed level using the bed probe. Printer specific STL are in each printer directory. Attempt to home Z-axis while using a BLTouch or CRTouch without a Z endstop pin. Because of “z_hop: 4”. If using "probe:z_virtual_endstop" then do not define a position_endstop in the stepper_z config section. My Marlin config is configured like this: /** * Enable this option for a probe connected to the Z-MIN pin. 00 pin on the SKR 1. Basic Information: Printer Model: CR10S PRO V2 MCU / Printerboard: MANTA M5P + EBB36 CANBus Toolboard klippy (9). Vedere il comando MANUAL_PROBE per i dettagli sui parametri e sui comandi aggiuntivi disponibili mentre lo strumento è attivo. We would like to show you a description here but the site won’t allow us. 4. #contact_latency_min: 0. Strain gauge based probes are the industry standard in the machine tool world (e. # main difference compared to most probes is to disable. Code. Blame. This support is referred to as "multi-mcu homing". This document describes Klipper's stepper phase adjusted endstop system. Dec 29, 2021 · Trying out Klipper for the first time. Updating your Klipper config for Tap. ## you then should call CALIBRATE_Z as one of the last lines on your PRINT_START to set the Z offset dinamically # The X and Y coordinates (in mm) for clicking the nozzle on the # Z endstop. It will not work with the virtual pin of the probe configured as endstop! A (magnetic) switch based probe at the print head; Both, the Z endstop and mag-probe are configured properly and homing and any kind of bed leveling are working. , Manual leveling - Klipper documentation. — You are receiving this because you were mentioned. 3 KB) Describe your issue: …I am using Omron Proximity Switch TL-Q5MC1-Z as my probe. klipper3d. And give me trouble as shown in title "Endstop z still triggered after retract". See the documents described above to choose one of them. I use a probe and still use Z_ENDSTOP_CALIBRATE along with PROBE_CALIBRATE. 10 pin on the SKR 1. When the printer is switched on, the positions of the axes are not known. Run the appropriate command in the OctoPrint terminal window. I even tried plugging the white and black Klipper can help you and your machine produce beautiful prints at a fraction of the time. Position the toolhead far from the bed, issue a G28 (or PROBE if not using probe:z_virtual_endstop), wait until the toolhead starts to move down, and stop the movement by very gently touching the pin with your nail. x:open y:open z:open. The reference postion should be the location on the bed where a Z_ENDSTOP_CALIBRATE paper test is performed. switch_xy_position: X,Y A Z endstop where the tip of the nozzle drives on a switch (like the stock Voron V1/V2 enstop). This feature can be useful to simplify Mar 13, 2018 · The probe section also creates a virtual probe:z_virtual_endstop pin. Use an automated tool to determine precise Z heights! Klipper has several helper scripts available (eg, MANUAL_PROBE, Z_ENDSTOP_CALIBRATE, PROBE_CALIBRATE, DELTA_CALIBRATE). 3 KB) klippy. Klipper is configured to know about how far above bed the endstop is. Virtual endstop problem. 2%. ## --- BIQU Microprobe Klipper configuration ---. Shell 17. # new additions for beacon safe_z_home functionality. When ı want to home all axes it home first x and y (normally) but then the z axis sensor being triggered. I noticed when checking the endstops earlier they all were showing open, so I decided to go through each one to confirm each would show triggered when activated and noticed the z endstop isn’t working because it was unplugged when the bl touch was added. This works, but then you need to determine your z-offset with the endstop and, e. What should be done just remove the entire line or cha Instead of letting the probe pin touch the print bed, let it touch the nail on your finger. 12 KB. Ensure that your nozzle is hitting the center of the pin. According to your log you are homing with an endstop for Z, but you also have a BLTouch. Endstop phase. cfg, inside [stepper_z], you should not write. Oct 3, 2022 · relative_reference_index #何番目のインデックスを基準(position_endstop)として扱うのか数値で指定。. log. cfg. Oct 2, 2022 · The button is being shown by Fluidd. 607 lines (507 loc) · 19. May 16, 2022 · George May 16, 2022, 3:14pm 2. The. klippy. Along with specifying the endstop_pin probe, change your sensor_pin = PC1 parameter in the BL Touch statement to sensor_pin = ^PC1 to enable the internal pull up in the MCU as the BL Touch pin Almost all endstop switches can safely be depressed a small distance beyond their trigger point. Then during bed mesh calibration, it will use the probe to acurately determine how far z endstop is and adjust accordingly. ) cd ~/klipper ; get fetch ; git checkout origin/work-probe-20170609 ; sudo service klipper restart Jan 18, 2024 · # If you prefer a direct serial connection, in "make menuconfig" # select "Enable extra low-level configuration options" and select # serial (on USART3 PB11/PB10), which is broken out on the 10 pin IDC # cable used for the LCD module as follows: # 3: Tx, 4: Rx, 9: GND, 10: VCC # Flash this firmware by copying "out/klipper. Jul 28, 2021 · A quick guide on setting your probes Z offset in Klipper. 0 I just wonder how to reliably determine the offsets with this kind of probe. 2 boards x2 OR SKR E3 Turbo. (It also has homing_override code that can be used to position the head prior to Z probing. g. Z_OFFSET_APPLY_ENDSTOP¶ Z_OFFSET_APPLY_ENDSTOP: Take the current Z Gcode offset (aka, babystepping), and Python 82. Currently, an eddy current probe can not be used for Z homing. A typical endstop switch has an accuracy of around 100 microns. log I’m trying to upgrade to a Tronxy Black inductive sensor. I have a Creality board V2. Nov 24, 2018 · When you set the endstop position to -2 Klipper (and bed_mesh) does indeed assume the bed as at Z=0, ie 2mm higher than where your endstop triggered. # Distance to retract before x/y homing moves. log file (use zip to compress it, if too &hellip; Ensure that the endstop pin is square on top, otherwise it can cause your Z offset to drift as it rotates over time. Reply to this email directly, view it on GitHub, or unsubscribe. 1. SKR1. This is not an official Klipper support channel and poorly moderated so ymmv. I have my BLTouch connected to Z-STOP on the board and it works fine with Marlin. It is connected to dedicated port for proximity sensor given in BTT Octopus at 24V. Jul 8, 2024 · If you want to enable Z-Homing/Endstop for the eddy do the following things: Under your [stepper_z] in printer. 0 to 100 or even 50. Z_OFFSET_APPLY_ENDSTOP¶ Z_OFFSET_APPLY_ENDSTOP: prende l'offset Z Gcode I've had this working before for X and Y so I'm wondering if there's a bug with using the probe:virtual_endstop with a tmc_2209_stepper_z:virtual_endstop in the probe section. The default for the value for the endstop position is -0. the microwitch Endstop and also a Jul 22, 2023 · Now, you have set some aliases for the BL Touch and you have a [probe] parameter, but the pin argument in it doesn’t match the pins in the alias statement. History. 2. İt works at first but now it behave strange. 5mm) for the Z position_endstop. ️ 1 lenne0815 reacted with heart emoji All reactions If the BL-Touch will be used to home the Z axis then set endstop_pin: probe:z_virtual_endstop in the [stepper_z] config section and add a [homing_override] config section to raise the z-axis, home the x/y-axis, move to the center of the bed, and home the z-axis. 4 turbo, When homing Z, printer shuts down. log Fill out above information and in all cases attach your klippy. The probe is working perfectly fine, I have checked it many Gefällt dir der Kanal? Lass gerne ein Abo da! Mein Onlineshop für Filament und Ersatzteile: https://www. klicky-probe. Z_ENDSTOP_CALIBRATE [SPEED=<speed>]: esegue uno script di supporto utile per calibrare un'impostazione di configurazione Z position_endstop. BLtouch does it's 3 clicks and startup and is light up red as normal. cabinfourus June 26, 2022, 11:25pm 5. You may have to do it twice, since the ADMIN MOD. Then, run the CALCULATE_SWITCH_OFFSET. MCU / Printerboard: 4. I get a message of “Endstop z still triggered after retract” I’ve tried going through steps on this site (Connecting BL-Touch | klipper) but didnt work. Klipper plugin for self-calibrating z-offset. I used the 2. Or may be you need to invert the behaviour of the sensor, in this case: endstop_pin: !PE1. Note that your current endstop may not be PA5 so just look for the line that matches your current endstop and comment it Instead of letting the probe pin touch the print bed, let it touch the nail on your finger. And with triggering z axes probe it didnt make homing for z axes. Start by declaring a probe_eddy_current config section in the printer. I was advised to run the 'PROBE_CALIBRATE' command which after the printer performs a probe and shows a measurement on screen, i then type 'ACCEPT', which states that 'Manual probe failed! Use TESTZ commands to possition the nozzle prior to running ACCEPT. I recently installed Klipper on my E3V2 whit mainsail. Any help would be great. 8%. Send a QUERY_ENDSTOPS command in the Console; It should return with the following status: x:open y:open z:open. Everything else seems to work (motors, heaters, endstops, fans) except the virtual endstop. position_min: -5 position_endstop: 0 position_max: 235. The problem is i have a Bl-Touch on my printer connected to the bl touch pins on the board and when i try to make the endstop pin to (endstop_pin Nov 17, 2022 · Basic Information: Printer Model: Kingroon KP3s MCU / Printerboard: Kingroon (GD32F303) klippy. when I query endstops it shows X, Y open, and Z triggered. • Especially for testing purposes and to make sure not to damage the printer reduce homing_speed = 200. Cannot retrieve latest commit at this time. Either I set it up wrong or it does not like to be used with dual steppers on the z axis. Changes to z_offset doesn’t require a new bed mesh. 最初の数字は0(probe_count = 5, 5なら0-24までのいずれかを指定) BLTouchで検出した高さ-z_offset=ベッド面の高さ 中央付近なら(probe_count数-1)÷2. I assume this make Klipper act differently, as it then knows the printer has the TWO different systems. If you think there is a regression, try going back to the old code (for example, cd ~/klipper ; git checkout af981432f ; make ; sudo service klipper stop ; make flash ; sudo service klipper start ). This document describes how to use an eddy current inductive probe in Klipper. Z_OFFSET_APPLY_ENDSTOP¶ Z_OFFSET_APPLY_ENDSTOP: Take the current Z Gcode offset (aka, babystepping), and Mar 22, 2023 · In this step 15of how to build a Voron 2. Pasting your printer. These settings control printer motion on a delta printer. ***> wrote:  You either have 2 end stops or one probe. 3 and im going to use the 0. Hello. You can either add a gcode offset to your start gcode, or you can adjust the endstop positions of your A, B, and C motors. some materials must be more squished then other) and keep the Feb 7, 2022 · The provided SKR-mini-E3-V3. Be sure to check our “Knowledge Base” Category first. Triggering the endstop while it is still some distance from the bed reduces the risk of inadvertent bed TLDR: i use a sensorless endstop for homing zmax with a probe for finding the bed. # X, Y coordinate for homing z via contact. The Switchwire has the x endstop on the carriage, and homes by moving towards x max , to the right, So position of the x endstop will be the same as your max x size. 4. The probe z_offset will then be calculated from these measurements. To use it you must have a Z probe (BL Touch, Inductive sensor, etc). Check Klipper out on discord, discourse, or Klipper3d. bin" to a SD card and Probe dock (all the printers use the same) Probe dock mount (what attaches to the printer to dock the probe when not in use) The CAD with all the files is located Here. 1556. If you want to use the probe for homing you need to change the endstop_pin to probe:z_virtual_endstop. These seem like significant advantages of a load cell probe that are not easy to replicate with any other probing technology. cfg is not needed Describe your issue: Well, I had a semi-working configuration but then encountered some problems. y_offset: -29. Part integration successful, feeding it the required 12V and the sensor is able to halt the Z axis once in proximity. Update your Z endstop: Under the [stepper_z] block, you'll want to comment out your position_endstop and change your endstop_pin so that it uses the virtual Z endstop for Tap. log klippy. The z_offset is the distance between the nozzle and bed when the probe triggers. it's rare, maybe one in a thousand times it happens, but that's a head crash every ten or so times you read the mesh of the print. #home_z_hop: 5. Test your endstop’s accuracy using PROBE_Z_ACCURACY. endstop_pin: PE1. The klipper macros are here, the RRF here. この記事が気に入っ Jun 23, 2022 · jakep_82 June 26, 2022, 5:23am 4. log file. log Jun 3, 2024 · Star 9 9. It is most useful when using a Trinamic stepper motor driver that has run-time configuration. Roger that in regards to Pastebin. The right line must look like this one. It is labeled as position_endstop and can be found in the [stepper_z] section of the configuration file. Klipper supports a mechanism for homing with an endstop attached to one micro-controller while its stepper motors are on a different micro-controller. You have "endstop_pin: probe:z_virtual_endstop", right? May 31, 2021 · Getting Klipper setup on Ender 3 with 4. # # this macro is based on the great Annex magprobe dockable probe macros "#Originally developed by Mental Run a CALIBRATE_Z. mk_tom January 12, 2024, 7:23pm 3. Jul 30, 2022 · Suppose you have connected your sensor to a pin called PE1, as an example. Of course, your position_endstop must be in a way to stop the axis before it hits the bed. # deactivating the probe (PROBE_UP) after each sample. Not sure why it wouldn't work for you though. To verify the Sep 25, 2019 · My probe is connected to ar18. Try this one: Z_OFFSET_APPLY_PROBE. Feb 28, 2020 · On Mar 10, 2020, at 5:46 PM, Vlad Babii ***@***. It is mounted as per Voron Stealthburner guide. You may have to do it twice, since the Z_ENDSTOP_CALIBRATE [SPEED=<speed>]: Run a helper script useful for calibrating a Z position_endstop config setting. Mesh is a “map” of your bed flatness in order to compensate the bumps. May 6, 2021 · [stepper_z] endstop_pin: probe:z_virtual_endstop position_min: -2. 3614. # This macro was provided by discord user Garrettwp to whom i give my thanks for sharing it with me. Triggering the endstop while it is still some distance from the bed reduces the risk of inadvertent bed Endstop. The Klipper PROBE_CALIBRATE tool can be used to obtain this value - it will run an automatic probe to measure the probe's Z trigger position and then start a manual probe to obtain the nozzle Z height. 5, 117. Z_ENDSTOP_CALIBRATE [SPEED=<speed>]: Run a helper script useful for calibrating a Z position_endstop config setting. 7 board and BLTouch 3. The virtual endstop assumes that the bed has the same z offset for nozzle and probe at the homing position. It is recommended to set the z_offset to 0. Klipper probe config for the BIQU Microprobe (V1/V2) biqu_microprobe. General Discussion. # Test config for probe:z_virtual_endstop [stepper_x] step_pin: PF0 dir_pin: PF1 enable_pin: !PD7 microsteps: 16 rotation_distance: 40 endstop_pin: ^PE5 position_endstop: 0 position_max: 200 homing_speed: 50 [stepper_y] step_pin: PF6 dir_pin: !PF7 enable_pin: !PF2 microsteps: 16 rotation Klipper keeps shutting down with this error: Probe virtual endstop only useful as endstop pin. org/https://www. You’re currently telling the printer to use the diag pin on the Z driver for sensorless homing which is not a safe way to home and could lead to a head crash. kris3d. This feature is also used when a Z probe is on a different micro-controller than the Z stepper motors. As the sensor is a NC (normal close) sensor, it should be configured as "pin: ^ar18". June 13, 2024. The sensor can only be used for Z probing. Expected behavior The axis should home and deploy and utilize the probe to zero out the z axis. Because when I configure it the correct way, the result of "QUERY_ENDSTOPS" is always [probe] pin: !PB12 activate_gcode: probe_reset samples: 3 samples_tolerance: 0. For z_offset probably 0,0 but the rest looks tricky. EddyMI3D October 3, 2022, 3:20am 5. I have the BTT TMC2209 steppers and have used them before for sensorless homing on X and Y so I know they work. 4 Turbo klippy. I've gone through the sensorless setup instructions with a Apr 14, 2024 · Sineos April 14, 2024, 3:20pm 3. home_xy_position: 117. deIn diesem Video der BLTouch als Z-Endstop e Feb 19, 2023 · Basic Information: Printer Model: Ender 5 Plus MCU / Printerboard: BTT SKR 1. Renishaw). The BLtouch is plugged in per the M8P manual. Without the probe, move the nozzle to the center of the bed and perform a manual Z offset calibration by moving the nozzle down, step by step, until it barely touches the print surface. When I adjust the Z offset LIVE via the LCD or control panel, when the print is done I Can save it to either the endstop or the probe. 5. Klipper. Strange enough a normal endstop works fine?! My config: ##### [stepper_z] step_pin: PB3 dir_pin: !PB2 enable_pin: !PA5 microsteps: 16 rotation_distance: 8 # Use 4 for Ender5 versions The Z endstop position value is defined in the printer. As an aside, use the dedicated servo and probe sockets on the mainboard, not the z-endstop socket, the denoise/debounce is a little different and the very brief pulse from the bltouch can get lost using the endstops. log file (use zip to compress it, if too big). If anyone knows or Oct 10, 2023 · To get ONLY the BL Touch working, you need to change the endstop pin = ~PD29 parameter to endstop_pin: probe:z_virtual_endstop to pick up the BL Touch. Apr 1, 2024 · 10. Feb 23, 2022 · Prusa showed off the XL printer which has a load cell in the tool head used for Z homing, bed meshing and X/Y nozzle alignment. 2 with EZABL and mainsail/Klipper I think I need a endstop pin number cause my Z endstop shows triggered but I'm 100mm away from the nozzle. 3 Host / SBC- Raspi V3 klippy. Delta calibration involves finding the tower endstop positions, tower angles, delta radius, and delta arm lengths. When this is done, one should find that the Z_ENDSTOP_CALIBRATE command reports a small positive value (eg, . SKR Mini E3 V2 with BLTouch connected to Z-MIN - how do I configure that? Trying out Klipper for the first time. I am having trouble with the bltouch when homing. As you can see, it is configured as "pin: !ar18". 5 And the [probe] section: [probe] pin: ^your_pin_here x_offset: your_offset y_offset: your_offset z_offset: your_offset speed: 5. Almost all endstop switches can safely be depressed a small distance beyond their trigger point. 5 as a safety factor to prevent crashing the nozzle into the print surface during initial operations. cfg is not needed. # Not much different from a standard probe config. Code:PROBE_CALIBRATETESTZ Z=Further reading: https://www. log (1. # I have tweaked it a lot. It will move to start homing and then probe wont deploy at all. Values 0-3 are valid, with 3 tolerating the most noise. Notching your Z endstop pin (as described in the Voron manuals) can prevent it from rotating. * The probe replaces the Z-MIN endstop and Jan 16, 2022 · It means the head can move even past the endstop for the given distance, e. Mar 16, 2020 · I did everything in the documentation. However… no settings I’ve found thus far around probing (probe speed, sample retraction distance, lift speed, [de Aug 22, 2022 · Thanks! Result: No change in movement however I noticed there is a “!! Endstop x still triggered after retract” message reporting as well. That means the z endstop pin doesnt work. 75 lines (67 loc) · 1. org It's not clear which endstop you are having issues with. Locate the y-axis Endstop, which is the switch located to the right of the rear stepper motor; y-axis Endstop. In printers with a permanent probe, that also does the Z endstop, they have a stepper z entry of: endstop_pin:probe:z_virtual_endstop Versus a non-probe printer just has the pin of the Z endstop microswitch. Klipper verifies that any move are between position_min (Default 0) and position_max (the physical limit of your axes) Edit for more clarity. This functionality can improve the accuracy of traditional endstop switches. 0-klipper. Klipper is not recognizing my probe, always open or always closed by switching the logic back. * Enable this option for a probe connected to the Z-MIN pin. Jun 17, 2024 · Usually you just need one. 05 samples_tolerance_retries: 10 speed: 7 Disable both z endstops and use probe as a virtual z endstop. April 24, 2024. If everything is correct, it will print an estimated switch offset. Wires on bltouch on board are plugged in this order Z_ENDSTOP_CALIBRATE [SPEED=<speed>]: Run a helper script useful for calibrating a Z position_endstop config setting. Each one of these parameters has a non-obvious and non-linear impact and it is Aug 8, 2023 · Your X endstop is configured to be at position 20. Aug 9, 2023 · Basic Information: Printer Model: Voron Tridex MCU / Printerboard: BTT Octopus V1. Steps to reproduce. One may set the stepper_z endstop_pin to this virtual pin on cartesian style printers that use the probe in place of a z endstop. Convenience for removing the part. It is a LJ18A3-B-Z/AX proximity sensor which worked perfectly in Marlin. cfg was never a problem previously. May 10, 2022 · So I’m trying to set up my ender 3 with klipper using an skr 2 (because apparantly I need to rewire the screen to get it to work so screw that). I am not entairly new to klipper but i am trying mainsail for the first time, I came from fluidd. Also reduced probe speed just in case something goes wrong. nozzle_xy_position: X,Y # The X and Y coordinates (in mm) for clicking the probe's switch body # on the Z endstop. There are a few changes you'll need to make in order to get Tap working properly. * The probe replaces the Z-MIN endstop and is used for Z homing. M119 give only a,b,c endstops statuses We would like to show you a description here but the site won’t allow us. log (215. ek dx py nu wr nv oh sm fm az